2 Reference & Installation Manual
1.1 Specifications
Power input: 9 to 16 VDC, 100mA maximum
PGM current limit: 50 mA
Number of inputs: 2
Power indication: Yellow LED on
Locate indication:
Green and yellow LEDs flash simultaneously
Combus fault
indication: Red and yellow LEDs flash alternately
Tamper Switch: Yes (also used to deactivate locate)
LCD: Super Twisted Nematic display (STN), wide
viewing angle, 2 lines of 16 characters, backlight
and contrast adjustable
Read Range*: CR-R700 ISO PosiCard - up to 10cm (4”)
CR-R704 Key Tag - up to 6cm (2.5”)
Frequency: Exciter field - 125 KHz Pulse Modulated
Receive Low Frequency - 12.500 KHz
Receive High Frequency - 15.625 KHz
Compatibility: Any DGP-NE96 control panel or DGP-848 control
panel V2.20ACC and higher
Specifications may change without prior notice.
* The specified read range assumes no electrical interference and that
the card is presented parallel to the reader, with the reader installed and
operated as outlined in this manual. The read range will vary depending
on the type of card used. The larger the card, the greater the read range.
The read range may decrease if the reader is mounted on metal.
DGP2641R_ei00.fm Page 2 Thursday, July 22, 2004 4:16 PM