www.paradox.caModules Programming GuideProgramming MethodsThe modules can be programmed using the following methods:1) Through the WinLoad Security
10 - Digiplex Modules Programming GuideRefer to Appendix 1: Programming PGMs on page 41 for the PGM Table. Only Event Groups 000 to 055 can be used t
Digiplex Modules Programming Guide - 11Annunciator ModuleProgram the DGP2-ANC1 using the Winload Software or the control panel’s Module Broadcast f
12 - Digiplex Modules Programming GuideOutdoor High-Security Digital Motion Detector ModulesOperational ModeDigigard DG85 can function in two operati
Digiplex Modules Programming Guide - 13Motion Detector ModulesU = Default settingSECTION [001] : General OptionsOption OFF ON [1]Single/
14 - Digiplex Modules Programming GuideMagellan Wireless Expansion ModuleThe Module Broadcast feature of the Digiplex (DGP-848 and DGP-NE96) control
Digiplex Modules Programming Guide - 15Remote Control Programming= These button combinations are not available with the MG-REM1 remote control and
16 - Digiplex Modules Programming Guide4-PGM Expansion ModuleU = Default settingRefer to Appendix 1: Programming PGMs on page 41 for the PGM Table. A
Digiplex Modules Programming Guide - 171-PGM Expansion ModuleU = Default settingRefer to Appendix 1: Programming PGMs on page 41 for the PGM Table.
18 - Digiplex Modules Programming Guide8-zone Expansion Module* For the Base Time, using Level Programming (refer to page 1), press the and button
Digiplex Modules Programming Guide - 194-zone Expansion Module* For the Base Time, using Level Programming (refer to page 1), press the and butt
Table of ContentsGrafica Graphic LCD Keypad Module... 3
20 - Digiplex Modules Programming Guide1-zone Expansion ModuleINPUT SPEED = BASE TIME x TIME VALUE (Default: 600mS)U = Default settingSECTION [001] :
Digiplex Modules Programming Guide - 21Printer ModuleU = Default settingSECTION [001] : Partition Assignment SECTION [002] : Automatic Printing of
22 - Digiplex Modules Programming GuideU = Default settingSECTION [007] : Automatic Printing of Zone Status (41 to 48) SECTION [008] : Automatic Prin
Digiplex Modules Programming Guide - 23U = Default settingRefer to Appendix 1: Programming PGMs on page 41 for the PGM Table. Only Event Groups 000
24 - Digiplex Modules Programming Guide** Program the APR3-PRT1’s manual printing feature as you would a PGM. Refer to Appendix 1: Programming PGMs o
Digiplex Modules Programming Guide - 25InTouch Voice-Assisted Arm/Disarm ModuleU = Default settingSection Data Description Default[001] __/__/__ (0
26 - Digiplex Modules Programming GuideAccess Control ModuleU = Default setting* = V2.0 or higher** = V1.1 or higher*** = V1.02 or higherEnable optio
Digiplex Modules Programming Guide - 27For Access Control Modules version 2.0 or higher, the End Time can be set earlier than the Start Time. Pleas
28 - Digiplex Modules Programming GuideEnter the desired section to delete the corresponding access card(s).Note 1: PIN Entry On PosiPIN (DGP-NE96 on
Digiplex Modules Programming Guide - 29Power Supply ModuleRefer to Appendix 1: Programming PGMs on page 41 for the PGM Table. Only Event Groups 000
Digiplex Modules Programming Guide - 3Grafica Graphic LCD Keypad ModuleGrafica Keypads can be used with DGP-848 and DGP-NE96 control panels only. G
30 - Digiplex Modules Programming GuideModule Connection DrawingsModule Connection OverviewModule LED IndicationsGreen LOCATE LED (sometimes seen as
Digiplex Modules Programming Guide - 31Grafica Graphic LCD Keypad Module (DNE-K07)Please Note: The Grafica keypad is best viewed at an angle betwee
32 - Digiplex Modules Programming GuideLCD Keypad Module (DGP2-641/BL/R/RB) 48-Zone LED Keypad Module (DGP2-648)LCD Keypad (DGP2-641/BL/R/RB)Memory K
Digiplex Modules Programming Guide - 33Annunciator Module (DGP2-ANC1)Outdoor High-Security Digital Motion Detector Module (DG85)Remove B from any A
34 - Digiplex Modules Programming GuideMotion Detector Modules (DGP2-50/60/70)PCB Height AdjustmentDGP2-50/60/70 is designed for optimal performance
Digiplex Modules Programming Guide - 35Magellan Wireless Expansion Module (MG-RCV3)4-PGM Expansion Module (APR3-PGM4) 1-PGM Expansion Module (APR3-
36 - Digiplex Modules Programming Guide4-zone Expansion Module (APR3-ZX4)One-zone Expansion Module (DGP2-ZX1)Connect the detection devices to the APR
Digiplex Modules Programming Guide - 37Printer Module (APR3-PRT1) InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2)Refer to Module Connection Ov
38 - Digiplex Modules Programming GuideAccess Control Module (DGP2-ACM1P)If you are not using the DGP2-ACM1P’s on-board power supply, connect the “re
Digiplex Modules Programming Guide - 39Power Supply Module (DGP2-PS17) Door Contact Module (DGP2-ZC1)Refer to Module Connection Overview on page 30
4 - Digiplex Modules Programming GuideCopy Contents of the Grafica Keypad to the Memory Key:1) Insert the Memory Key onto the keypad’s connector (ref
40 - Digiplex Modules Programming GuideHub and Bus Isolator Module (APR3-HUB2)From other modules or a Spectra or Digiplex control panelTo other combu
Digiplex Modules Programming Guide - 41Appendix 1: Programming PGMSA PGM is a programmable output that toggles to its opposite state (i.e. a normal
42 - Digiplex Modules Programming Guide004 (cont’d) Non-reportable Event000NEware User Login 010 010NEware User Logout 011 011User Initiated Callup 0
Digiplex Modules Programming Guide - 43015 Disarm with Keyswitch000 Keyswitch numbers 001 to 032 001 to 032255 Any keyswitch Not Used Not Used016 D
44 - Digiplex Modules Programming Guide030 Special Alarm000Emergency Panic (Keys 1 & 3) 000 000Medical Panic (Keys 4 & 6) 001 001Fire Panic (
45 - Digiplex Modules Programming Guide040Fail to Communicate on telephone Number000 Telephone Number 001 to 004 001 to 004255 Any telephone number N
NOTE 1: 000 = Occurs in all partitions enabled in the system (refer to the appropriate control panel Programming Guide).001 = Partition 1 003 = Partit
** Keyswitch‡ Refer to the Magellan™ Reference and Installation Manual for remote control button programming instructions.WarrantyParadox Security Sys
780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450)491-7444 Fax: (450) 491-2313www.para
Digiplex Modules Programming Guide - 5LCD Keypad ModuleThe keypad’s serial number can be found on the keypad’s PC board. The keypad’s serial number
6 - Digiplex Modules Programming Guide† Section/option is only available with DGP2-641R/RB.‡ Section/option is only available with DGP2-641/BL† Secti
Digiplex Modules Programming Guide - 7Table 1: Message Programming Special Function KeysTable 2: Alphanumeric KeysTable 3: Special CharactersKey Fu
8 - Digiplex Modules Programming GuideUsing the Memory KeyDownload Contents of the Memory Key to the LCD Keypad1) Insert the Memory Key onto the keyp
Digiplex Modules Programming Guide - 948-Zone LED Keypad ModuleThis model does not support installer programming capabilities, therefore you cannot