DGP2-641R LCD Keypad Module 17n
5.2.4 Relock Door
S
ECTION [006]: OPTION [6]
The locking device will remain unlatched during the Door
Unlocked Period (see section 5.2.2 on page 16), but once the
door is opened it can be programmed to latch as soon as the
door closes or latch immediately even if the door has not
closed.
Option [6] OFF = Locking device latches immediately (default)
Option [6] ON = Locking device latches when door closes
5.2.5 Door Unlocked Schedule
S
ECTION [017]
The Door Unlocked Schedule determines the hours, days, and
holidays that the door will remain unlocked. Therefore, users
will not have to present their Access Control Cards to the reader
in order to gain access to an Access Control Door during the
Door Unlocked Schedule. The schedule consists of two
programmable time periods called “Intervals” that determine the
time of day and which days the users will be granted access.
When a schedule is programmed with “H”, users will have
access during the days programmed in the control panel (refer
to the DGP-848 or DGP-NE96 Reference & Installation
Manual).
Program the Start Time and End Time according to the 24-hour
clock within the same day. Use Feature Select Programming to
set the options representing the Days.
Option Day Option Day
[1] Sunday (S) [5] Thursday (T)
[2] Monday (M) [6] Friday (F)
[3] Tuesday (T) [7] Saturday (S)
[4] Wednesday (W) [8] Holidays (H)
DGP2641R_ei00.fm Page 17 Thursday, July 22, 2004 4:16 PM