14 Reference & Installation Manual
Option [2] OFF= Beep disabled: Communicator Troubles
Option [2] ON = Beep enabled: Communicator Troubles
Option [3] OFF= Beep disabled: Module and Combus Troubles
Option [3] ON = Beep enabled: Module and Combus Troubles
Option [4] OFF= Beep disabled: all Zone Troubles
Option [4] ON = Beep enabled: all Zone Troubles
4.12 Keypad Tamper Enable
SECTION [006]: OPTION [5]
With tamper enabled and the on-board tamper switch is triggered, a
Tamper report will be sent to the control panel via the combus.
Option [5] OFF= Keypad's tamper is disabled (default)
Option [5] ON = Keypad's tamper is enabled
4.13 Time Format
SECTION [005]: OPTION [7]
This feature determines whether the time shown on the screen will be
displayed using the International time format (24Hr. clock) or the US
time format (AM/PM).
Option [7] OFF= Time uses the International time format (default).
Option [7] ON = Time uses the US time format.
4.14 Combus Voltmeter
The combus voltmeter displays the real-time voltage and verifies if the
combus is supplying sufficient power at the keypad module’s location.
Readings will appear on the LCD screen. A reading of 10.5V indicates
that the voltage is too low. This may occur when too many modules are
connected to the combus, a module is installed too far from the panel or
if the system is running on the battery. In some cases adding an
DGP2641R_ei00.fm Page 14 Thursday, July 22, 2004 4:16 PM