DGP2-641R LCD Keypad Module 13n
4.9 Beep on Exit Delay
SECTION [004]: OPTION [2]
The keypad can beep once every second during the Exit Delay Timer.
During the final 10 seconds, it will beep more rapidly to provide a final
warning before the area is armed.
Option [2] OFF= Exit Delay beep disabled
Option [2] ON = Exit Delay beep enabled (default)
4.10 Chime on Zone Closure
SECTION [004]: OPTION [4]
During the Chime Zone Time Period that the user sets, the keypad can
emit an intermittent beep whenever a zone with the Chime feature
enabled closes (see DGP-848 or DGP-NE96 User Manual for details on
Chime Zones). If the user does not set the Chime Zone Time Period and
this option is enabled, the Chime Zones will always beep upon closure.
Option [4] OFF= Chime on Zone Closure disabled (default)
Option [4] ON = Chime on Zone Closure enabled
4.11 Beep on Trouble
SECTION [005]: OPTIONS [1] TO [4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a trouble
condition from the Trouble Groups occurs in the system. The intermittent
beep will remain activated until the user enters the Trouble Display or if the
trouble is resolved. For a list of the troubles, see the
DGP-848 or DGP-
NE96
Reference and Installation Manual. The intermittent beep will be re-
initialized whenever the trouble condition re-occurs.
O
ption [1] OFF= Beep disabled: System Troubles and Clock Loss
Option [1] ON = Beep enabled: System Troubles and Clock Loss
DGP2641R_ei00.fm Page 13 Thursday, July 22, 2004 4:16 PM