Digiplex LCD Keypad 11n
4.8 Muting
Section [004]: Option [1]
The keypad can be programmed not to emit audible sounds,
including Chimed zones. During Muting, the keypad will only
emit the Confirmation Beep, Rejection Beep, and beep when a
button is pressed.
4.9 Beep on Exit Delay
Section [004]: Option [2]
The keypad can beep once every second during the Exit Delay
Timer. During the final 10 seconds, it will beep more rapidly to
provide a final warning before the area is armed.
4.10 Chime on Zone Closure
Section [004]: Option [4]
During the Chime Zone Time Period that the user sets, the
keypad can emit an intermittent beep whenever a zone with the
Chime feature enabled closes (see DGP-848 or DGP-NE96 User
Manual for details on Chime Zones). If the user does not set the
Chime Zone Time Period and this option is enabled, the Chime
Zones will always beep upon closure.
Option [1] OFF = Audible sounds (default)
Option [1] ON = Mute
Option [2] OFF= Exit Delay beep disabled
Option [2] ON= Exit Delay beep enabled (default)
Option [4] OFF = Chime on Zone Closure disabled (default)
Option [4] ON = Chime on Zone Closure enabled