14 System Manager’s Manual
5.5 USER OPTIONS
Options [1] and [2]: Master Feature
When option [1] is OFF, the User cannot program other Users into the system.
When option [1] is ON and option [2] is OFF, the User can only modify existing User Access Codes.
When both options [1] and [2] are ON, the User has Full Master rights. The User can create or modify User
Access Codes, User Options, User Access Control Options, Access Card Numbers and Area Assignments
according to their own programming. For example, if the Full Master User has access to area #1 and option [4]
(Bypass) only, the Full Master User can only assign area #1 and option [4] to other Users in the system.
Option [3]: Duress
When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a User to arm
or disarm an area(s). By entering a User Access Code (P.I.N.) reserved for the Duress feature, the system will
arm or disarm the area(s), and then send a silent alarm to the Central Monitoring Station.
Option [4]: Bypass
When option [4] is ON, the Bypass feature is enabled. This feature allows the User to deactivate zones when
arming the area(s).
Option [5]: Arm Only
When option [5] is ON, the Arm Only feature is enabled. The User can arm assigned areas with either a card or
code, but cannot disarm. When the option is OFF, the User can either arm or disarm assigned areas.
Option [6]: Stay & Instant Arm
When option [6] is ON, the Stay and Instant Arm features are enabled. The User can now Stay or Instant Arm
their assigned areas.
Option [7]: Force Arm
When option [7] is ON, the Force arm feature is enabled. The User can now Force arm their assigned areas.
Option [8]: Area Access
When option [8] is ON, the keypad will permit access to all the areas assigned to the User Access Code. When
option [8] is OFF, the keypad will only permit access to the areas it controls. For example, the keypad is
assigned area 1 only, and your User Access Code is assigned areas 1 to 4. If the option is ON, you can access
all four areas from the keypad. If the option is OFF, you can only access area 1.
By default all Users can Regular arm the system.
5.6 ACCESS CONTROL USER OPTIONS
Option [1]: Access Card is Activated
When option [1] is ON, the Access Control Card is activated and can be used when Access Control is enabled
in the system. When the option is OFF, the Access Control Card cannot be used.
Option [2]: Disarming with Access Card
When option [2] is ON, a User’s Access Control Card can unlock and disarm an armed Access Control Door
(see section 6.2.2 on page 15).
For option [2] to function in the ON position, option [5] “Arm Only” in the User Options
must be disabled (refer to section 5.5 on page 14).
Option [3]: Card with Extended Unlocked Period
When option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time
period programmed into each Access Control Door by your Installer that extends the unlocked time of the door.
For example, if your Installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked
Period to 15 seconds, then a User Access Code with “Extended Unlocked Period” enabled will have a total of
45 seconds to pass through the door.
Options [4] to [7]: Arming with Card
Options [4] to [7] define the type of arming when arming with an Access Control Card (refer to section 6.2.1 on
page 15). You can either Regular arm, Stay arm, Instant arm, or Force arm.
[4] ON, [5] to [7] OFF = Regular Arm
[4] & [5] ON, [6] & [7] OFF = Stay Arm
[4] & [6] ON, [5] & [7] OFF = Instant Arm
[4] & [7] ON, [5] & [6] OFF = Force Arm