Digiplex Control Panel (DGP-848) - V4.1Reference and Installation ManualIncludes DGP2-641BL/RB Installation InstructionsDGP-848
6 Reference & Installation Manual2.9 Programmable OutputsThe Digiplex control panel comes standard with PGM1 and PGM2. PGM3 to PGM5 are optional.
DGP-848 Control Panel 72.12 Double Zone ConnectionsEnabling the ATZ feature (see section 4.8 on page 16) allows you to install two detection devices
8 Reference & Installation Manualsmoke detector sends a CleanMeTM signal, the control panel will generate a Zone Fault trouble and if programmed w
DGP-848 Control Panel 93 Programming MethodsThe Digiplex control panel can be programmed using the WinLoad software, the Paradox Memory Key, or manu
10 Reference & Installation Manual3.6 Level ProgrammingIn the sections requiring Level Programming, only one option can be selected.For LCD keypad
DGP-848 Control Panel 114 Zone ProgrammingAll detection devices connected to the control panel, keypads and zone expansion modules must be assigned
12 Reference & Installation Manual4.1 Zone NumberingSECTIONS [001] TO [048]The Zone Numbering feature allows you to assign any detection device in
DGP-848 Control Panel 13Figure 15: Delayed 24-hr. Fire Zone4.2.8 Standard 24Hr Fire ZoneSECTIONS [101] TO [148]: FIRST DIGIT = AFor details how to co
14 Reference & Installation Manual4.4.2 Bypass ZonesSECTIONS [101] TO [148]: OPTION [2]Only zones with option [2] enabled can be Manually Bypassed
DGP-848 Control Panel 15Table 5: Hebrew Keypad Letter AssignmentTable 6: Russian Keypad Letter AssignmentTable 7: Special Characters CatalogueTable 8
16 Reference & Installation Manual4.6 Input SpeedSECTIONS [201] TO [216](000 to 255 X 20msec,default: 600ms) The Input Speed defines how quickly t
DGP-848 Control Panel 175 Keyswitch ProgrammingThe Digiplex control panel can support up to 8 keyswitch zones in addition to the 48 standard zones.
18 Reference & Installation ManualFigure 19: Example of Keyswitch Numbering5.2 Keyswitch DefinitionsSelect one of the keyswitch definitions (also
DGP-848 Control Panel 195.4.5 Instant Arming (Keyswitch)SECTIONS [149] TO [156]: OPTION [8]This option is identical to Stay arming except that all ar
20 Reference & Installation Manual6.6 No Movement Auto-ArmingSECTIONS [505], [509], [513], [517]: OPTION [6]If no movement occurs in a partition&a
DGP-848 Control Panel 21[221] will not lockout the keypad, the control panel will transmit the Keypad Lockout report code programmed in section [705]
22 Reference & Installation Manual7 Alarm Options7.1 Bell/Alarm OutputSECTION [500]: OPTIONS [5] TO [8]When a partition generates an alarm, the c
DGP-848 Control Panel 23Regardless of whether the partition is armed or disarmed when a tamper or wire fault occurs, the Zone Fault trouble will appe
24 Reference & Installation Manual8 Event ReportingFigure 20: Event ReportingRelated FeaturesDelay Before Alarm TransmissionSection [256]Pager Fo
DGP-848 Control Panel 258.1 Reporting EnabledSECTION [521]: OPTION [3] This option will either enable or disable event reporting. With option [3] on
DGP-848 Control PanelTable of ContentsIntroduction... 1Features...
26 Reference & Installation ManualSection [680]• Auto Zone Shutdown: a zone communicates more than the programmed number of transmissions in a sin
DGP-848 Control Panel 27Section [718]• WinLoad Access: the panel ended communication with WinLoad• Installer In: installer has entered the programmin
28 Reference & Installation ManualIf the control panel still fails to report to a monitoring station telephone number after reaching the Maximum D
DGP-848 Control Panel 29Alarm Restore CodesSection [792]Sets all report codes in sections [655] to [680] with the default values from the Automatic R
30 Reference & Installation Manual9.4 Busy Tone DetectionSECTION [521]: OPTION [6]Option [6] ON = the control panel can immediately hang up if it
DGP-848 Control Panel 31Figure 21: Ground Start CircuitKissoff: After receiving a handshake from the monitoring station, the control panel activates
32 Reference & Installation Manual11 PGM Programming Table*Note1: 0 = All partitions enabled in the system (see section 12.5 on page 36)1 = Parti
DGP-848 Control Panel 339 Access Granted0 Door 01 Door 02 Door 03 Door 04 Door 05 Door 06 Door 07 Door 081 Door 09 Door 10 Door 11 Door 12 Door 13 Do
34 Reference & Installation ManualC Auto Zone Shutdown0 Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zone 07 Zone 081 Zone 09 Zone 10 Zone 11 Z
DGP-848 Control Panel 35‡ You must program a remote control button with a Utility Key option.12 System Settings & Commands12.1 Hardware ResetPer
Reference & Installation ManualPower Save Mode ... 37Auto Trouble Shutdown ...
36 Reference & Installation Manual12.4 Installer Code LockSECTION [990]Enter 147 into section [990] to lock all programming. When 147 is programme
DGP-848 Control Panel 37on the module will begin to flash until the serial number is re-entered into section [952] or the appropriate tamper or unloc
38 Reference & Installation Manual13 Access CodesThe Digiplex control panel supports 95 user access codes, 1 System Master Code, and 1 Installer
DGP-848 Control Panel 3913.5 User OptionsThe User Options define how each user access code can arm or disarm the system. Regardless of these settings
40 Reference & Installation ManualAccess Control features. This can be used to disable a lost or stolen card without deleting the user access code
DGP-848 Control Panel 4114 Access ControlAccess control is an industry term for a system that monitors and regulates the passage into and out of pro
42 Reference & Installation Manualone partition assigned to the door. An “OR” door will arm or disarm only the partitions that it has in common wi
DGP-848 Control Panel 4314.10 Global Access Door Features14.10.1 Burglar Alarm On Forced DoorSECTION [537]: OPTION [5]An Access Door can be assigned
44 Reference & Installation Manual15 WinLoad SoftwareThe Winload software is not verified by UL.15.1 Answering Machine OverrideSECTION [441]When
DGP-848 Control Panel 4515.9 Call Back FeatureSECTION [522]: OPTION [1]For additional security, when a computer using WinLoad attempts to communicate
DGP-848 Control Panel 11 IntroductionParadox Security Systems has once again redefined the boundaries of the security industry and is proud to intro
46 Reference & Installation Manual3) Press the [DISARM] key. If the users have access to more than one partition, they can press the key correspon
DGP-848 Control Panel 47Figure 23: Normal and Confidential Mode16.5.1 Scroll RestartIn Normal mode the keypad will scroll though the status of the di
48 Reference & Installation ManualIf the Access Control feature is enabled in the system and the option Door Access during Clock Loss is ON (secti
DGP-848 Control Panel 4916.10 Event Record DisplayThe Event Record Display can only be viewed through an LCD or Grafica keypad. The Event Record Disp
50 Reference & Installation Manual17 Appendix 1: DGP2-641BL/RB Installation Instructions1.0 INSTALLATIONThe DGP2-641BL/RB is connected to the con
DGP-848 Control Panel 51Figure 29 : Access Control Connections2.0 PROGRAMMINGProgramming the DGP2-641BL/RB keypad module is simple. Enter Module Pro
52 Reference & Installation Manual3.4 Display Entry Delay TimerSECTION [003]: OPTION [3]The Entry Delay Timer will be programmed to provide the us
DGP-848 Control Panel 53battery. In some cases adding an external power supply may correct the situation.1) From Normal Mode press and hold the [0] k
54 Reference & Installation Manualunlocked when the REX device detects movement and users on either side of the door will be able to open the door
DGP-848 Control Panel 555.3.4 Door Left Open Pre-Alarm TimerSECTION [011]This timer will trigger the Door Left Open Pre-Alarm before the end of the D
2 Reference & Installation Manual2 Installation2.1 Location & MountingBefore mounting the cabinet, push the five white nylon mounting studs i
56 Reference & Installation Manual[STAY] - Insert SpacePressing the [STAY] key inserts a blank space in the current cursor position.[FORCE] - Dele
DGP-848 Control Panel 5718 IndexAAC Power ... 2Access Alarm ...
58 Reference & Installation ManualDisabledWireless Transmitter Supervision ... 22Disarm with Access Card ...
DGP-848 Control Panel 59As a 4-wire smoke detector ... 8Connections ...
60 Reference & Installation Manual19 WarningsFCC WarningsImportant InformationThis equipment complies with Part 68 of the FCC rules subpart D and
DGP-848 Control Panel 61CL3R, CL3P, or substitute cable permitted by the National Electrical Code, ANSI/NFPA 70.20 WarrantyParadox Security Systems
62 Reference & Installation Manual
780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: 450 491-7444 Fax: 450 491-2313paradox.comPr
DGP-848 Control Panel 3Figure 3: Digiplex Control Panel PCB LayoutFor UL/C-UL warnings and requirements, see Warnings on page 60.For the hardwire conn
4 Reference & Installation Manual2.8 Calculating Power RequirementsTable 1: Milliamp Consumption TableSTEP 1: Using Table 1, calculate the total n
DGP-848 Control Panel 5Figure 4: Sample Power Requirement Calculations If in the above example you were to add an LCD Keypad (110mA) to the 30m (100ft
Commentaires sur ces manuels