Digiplex EVO641R Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Systèmes de contrôle d'accès de sécurité Digiplex EVO641R. Digiplex EVO641R Installation manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
paradox.com
Modules Programming Guide
Keypad Modules
Annunciator Module
Motion Detector Modules
Zone Expansion Modules
Access Control Module
Voice Assisted Modules
Accessory Modules
Integration Module
Internet Module
We hope this product performs to your complete satisfaction. Should you have any
questions or comments, please visit www.paradox.com and send us your comments.
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1

paradox.comModules Programming GuideKeypad ModulesAnnunciator ModuleMotion Detector ModulesZone Expansion ModulesAccess Control ModuleVoice Assisted M

Page 2 - Table of Contents

10 - Modules Programming GuideRefer to Appendix 1: Programming PGMs on page 52 for the PGM Table. Only Event Groups 000 to 055 can be used to program

Page 3 - DNE-K07 V1.4

Modules Programming Guide - 11The keypad will display up to a total of 48 zones, however any zone from 1 to 96 can be selected. Do not assign more

Page 4 - Memory Key Connector

12 - Modules Programming GuideDGP2-ANC1B V1.1Annunciator ModuleThe DGP2-ANC1’s serial number is located on the module’s PC board.U = Default Settings

Page 5 - [004]

Modules Programming Guide - 13DGP2-50/60 & DGP2-70Motion Detector ModulesRefer to DGP2-50/60/70’s connection drawing on page 42 for the locatio

Page 6 - [ 0 0 6 ]

14 - Modules Programming GuideDG85 V1.3Outdoor High-Security Digital Motion Detector ModulesOperational ModesThe DG85 can function in two different o

Page 7 - Message Programming

Modules Programming Guide - 15DG467 V1.0360° Ceiling Mounted Motion Detector ModuleOperational ModesThe DG467 can function in two different operati

Page 8

16 - Modules Programming GuideDG457 V1.0Digital Glassbreak DetectorOperational ModesThe DG457 can function in two different operational modes: combus

Page 9 - DGP2-648BL

Modules Programming Guide - 17DGP2-ZX1 V2.01-zone Expansion ModuleInput speed = Base Time X Time Value (Default: 600ms) U = Default settingSection

Page 10

18 - Modules Programming GuideAPR3-ZX4 V1.04-zone Expansion Module* For the Base Time, using Level Programming, press the and buttons to select a

Page 11 - Number to a zone

Modules Programming Guide - 19APR-ZX88-zone Expansion Module* For the Base Time, press the and buttons to select a value from 000 to 002 and th

Page 12 - DGP2-ANC1B V1.1

Table of ContentsModules Programming Guide...

Page 13 - DGP2-50/60 & DGP2-70

20 - Modules Programming GuideMG-RTX3 V1.1Magellan Wireless Expansion ModuleWhen using on an EVO96 version 1.52 or higher without an EVO641, enable o

Page 14 - DG85 V1.3

Modules Programming Guide - 21Table 4: PGM Option Programming Event Group Feature Group Start # End #PGMActivation*PGM1 [910] [911] [912] [913]PG

Page 15 - DG467 V1.0

22 - Modules Programming GuideDGP-LSN4 and DGP-SUB V1.1Listen-in ModuleU = Default settingSection [001] Substation 1 Partition AssignmentOptions OFF

Page 16 - DG457 V1.0

Modules Programming Guide - 23Section [005] General Option 1Options OFF ON[1]Module Tamper InputU Disabled N Enabled[2]Telephone Line MonitoringU

Page 17 - DGP2-ZX1 V2.0

24 - Modules Programming GuideSection [011] Substation 3 Page OptionsOptions OFF ON [1] Substation 3 can page Substation 1 N Disabled U E

Page 18 - APR3-ZX4 V1.0

Modules Programming Guide - 25[4]Audio Message on Entry Delay N Disabled U Enabled[5]Welcome Audio MessageU Disabled N Enabled[6]Goodbye Audio Mes

Page 19 - 8-zone Expansion Module

26 - Modules Programming GuideSection [021] Substation 2 Partition StatusOption OFF ON [1]Plays status of Partition 1 N Disabled U Enable

Page 20 - MG-RTX3 V1.1

Modules Programming Guide - 27Using the Memory KeyDownload Contents of the Memory Key to the Listen-In Module1) Insert the Memory Key onto the List

Page 21

28 - Modules Programming GuideDGP-ACM124-Wire Access Control ModuleU = Default settingSection [001] Partition AssignmentOption OFF ON [1]

Page 22 - DGP-LSN4 and DGP-SUB V1.1

Modules Programming Guide - 29Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.U = Default settingSection [004] P

Page 23

Modules Programming Guide - 3DNE-K07 V1.4 Grafica Graphic LCD Keypad ModuleGrafica Keypads can be used with DGP-848 and DGP-NE96 V1.3 or higher con

Page 24

30 - Modules Programming GuideThe DGP-ACM12 has a build-in supervised 1.5A switching power supply and needs to be connected to a transformer. Section

Page 25

Modules Programming Guide - 31APR3-PGM4 V2.04-PGM Expansion ModuleU = Default settingRefer to Appendix 1: Programming PGMs on page 52 for the PGM T

Page 26

32 - Modules Programming GuideAPR3-ADM2 V2.0Voice Assisted Arm/Disarm ModuleU = Default settingSection Data Description Default[001] __/__/__ (000 to

Page 27 - Combus Voltmeter

Modules Programming Guide - 33APR-PRT3 V1.0Integration ModuleU = Default settingSection [001] Partition AssignmentOption OFF ON

Page 28 - DGP-ACM12

34 - Modules Programming GuideSection [005] Automatic Printing of Zone Status (25 to 32)Option OFF ON [1]Print Status of Zone 25U Disabl

Page 29 - 12345678

Modules Programming Guide - 35Section [010] Automatic Printing of Zone Status (65 to 72)Option OFF ON [1]Print Status of Zone 65 (EVO1

Page 30

36 - Modules Programming GuideRefer to Appendix 1: Programming PGMs on page 52 for the PGM Table. Only Event Groups 000 to 055 can be used to program

Page 31 - APR3-PGM4 V2.0

Modules Programming Guide - 37Manual Printing ProgrammingSection Data Description Default[027] __/__/__ (000 to 255)** Miscellaneous Events (Event

Page 32 - APR3-ADM2 V2.0

38 - Modules Programming GuideDGP2-PS17 V1.0Power SupplyA 40VA transformer is required when selecting the 850mA battery charge current. Using a 20VA

Page 33 - APR-PRT3 V1.0

Modules Programming Guide - 39Module Connection DrawingsModule LED IndicationsGreen LOCATE LED (sometimes seen as LOC or LC):Power Up: Remains illu

Page 34

4 - Modules Programming GuideUsing the Memory KeyDownload Contents of the Memory Key to the Grafica Keypad:1) Insert the Memory Key onto the keypad’s

Page 35

40 - Modules Programming GuideGrafica Graphic LCD Keypad Module (DNE-K07)Please Note: The Grafica keypad is best viewed at an angle between 20° and -

Page 36

Modules Programming Guide - 41EVO641/EVO641R Access Control ConnectionsLCD Keypad Module (EVO641/EVO641R) 48-Zone LED Keypad Module (DGP2-648)Memor

Page 37 - Manual Printing Programming

42 - Modules Programming GuideAnnunciator Module (DGP2-ANC1B)Outdoor High-Security Digital Motion Detector Module (DG85)Remove B from any Annunciator

Page 38 - DGP2-PS17 V1.0

Modules Programming Guide - 43Motion Detector Modules (DGP2-50/60/70)PCB Height AdjustmentDGP2-50/60/70 is designed for optimal performance at a he

Page 39 - Module Connection Drawings

44 - Modules Programming GuideMagellan Wireless Expansion Module (MG-RTX3)Digital Ceiling Mounted Motion Detector Module (DG467)4-PGM Expansion Modul

Page 40

Modules Programming Guide - 454-zone Expansion Module (APR3-ZX4)One-zone Expansion Module (DGP2-ZX1)Connect the detection devices to the APR3-ZX4 i

Page 41 - Z1 terminal

46 - Modules Programming GuideListen-in Modules (DGP-LSN4 & DGP-SUB1)InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2)Reset JumperFirmware Upg

Page 42 - PCB HEIGHT ADJUSTMENT

Modules Programming Guide - 47Intergration module (APR-PRT3) 1) LED feedback2) 25-Pin Parallel Port: Connect the Printer Module’s 25-pin parallel p

Page 43 - PCB Height Adjustment

48 - Modules Programming GuideAccess Control Module (DGP-ACM12)Splice all cables hereConnecting Access Control Devices to the DGP2-ACM12Caution: Disc

Page 44 - PCB arrow with

Modules Programming Guide - 49Power Supply Module (DGP2-PS17) Door Contact Module (DGP2-ZC1)Caution: Disconnect battery before replacing the fuse.F

Page 45 - Detector

Modules Programming Guide - 5EVO641/EVO641R V1.0832-Character Blue LCD Keypad ModuleThe keypad’s serial number can be found on the keypad’s PC boar

Page 46

50 - Modules Programming GuideHub and Bus Isolator Module (APR3-HUB2)From other modules or a Spectra or Digiplex control panelTo other combus modules

Page 47 - Indications on page 39

Modules Programming Guide - 51VDMP3 Plug-in Voive DialerFor programming method, refer to panel programming guide.Attach support pin to EVO panel an

Page 48 - Paradoor 460

52 - Modules Programming GuideAppendix 1: Programming PGMSA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM

Page 49

Modules Programming Guide - 53004Non-reportable EventTLM Trouble (see NOTE 3 on page 58)000 000Smoke detector reset 001 001Arm with no entry delay

Page 50 - From other modules or a

54 - Modules Programming Guide012Special Arming000Auto Arming 000 000Arming by WinLoad 001 001Late to Close 002 002No Movement Arming 003 003Partial

Page 51 - VDMP3 Plug-in Voive Dialer

Modules Programming Guide - 55022Special Disarm Events000Auto Arm Cancelled 000 000One-touch Stay/Instant Disarm 001 001Disarming with WinLoad 002

Page 52 - Appendix 1: Programming PGMS

56 - Modules Programming Guide037Trouble Restore000TLM Trouble 000 000AC Failure 001 001Battery Failure 002 002Auxiliary Current Limit 003 003Bell Cu

Page 53

Modules Programming Guide - 57047Late to Arm by User000 User Codes 001 to 255 001 to 255 001 to 255001 User Codes 256 to 511 000 to 255 000 to 2550

Page 54

58 - Modules Programming GuideNOTE 1: 000 = Occurs in all partitions enabled in the system (refer to the appropriate control panel Programming Guide)

Page 55

Modules Programming Guide - 59** Keyswitch‡ Refer to the Magellan™ Reference and Installation Manual for remote control button programming instruct

Page 56

6 - Modules Programming Guide† Section/option is only available with EVO641R.‡ Section/option is only available with EVO641.Section [005] Beep on Tr

Page 57

paradox.comPRINTED IN CANADA 09/2007 MODULES-EP14For technical support in Canada or the U.S., call 1-800-791-1919, Monday

Page 58

Modules Programming Guide - 7‡ Section/option is only available with EVO641.Only Event Groups 000 to 055 and 070 can be used to program the module’

Page 59 - ** Keyswitch

8 - Modules Programming GuideTable 3: Special CharactersUsing the Memory KeyDownload Contents of the Memory Key to the LCD Keypad1) Insert the Memory

Page 60

Modules Programming Guide - 9DGP2-648BL48-zone LED Keypad ModuleThis model does not support installer programming capabilities, therefore you canno

Commentaires sur ces manuels