28 Reference & Installation Manual
If the control panel still fails to report to a monitoring station
telephone number after reaching the Maximum Dialing Attempts
(see section 8.6.1), the control panel will dial the selected backup
telephone number unless the Alternate Backup Option is enabled
(see section 8.6.3). When the Alternate Backup Option is enabled,
the control panel will dial the backup number after every failed
attempt.
8.6.1 Maximum Dialing Attempts
SECTION [257]
The number (001 to 255) programmed into section [257]
determines how many times the control panel will dial the same
monitoring station telephone number before proceeding to the next
number. Also refer to section 8.6.3.
8.6.2 Delay Between Dialing Attempts
SECTION [258]
This delay will determine the amount of time the control panel will
wait between dialing attempts. This delay can be set from 001 to
255 seconds.
8.6.3 Alternate Backup Option
SECTION [522]: OPTION [6]
With option [6] enabled in section [522], the control panel will dial
the selected backup telephone number after every failed attempt to
contact a monitoring station telephone number. Otherwise (option
[6] off), the control panel will only dial the backup telephone
number after the Maximum Dialing Attempts (see section 8.6.1) to
one monitoring station telephone number have failed.
8.7 Recent Close Delay
SECTION [219]
If after having armed the system, an alarm is generated within the
period programmed into section [219] (000 to 255 seconds), the
control panel will transmit the Recent Close report code
programmed into section [679].
8.8 Auto Test Report
SECTIONS [261] AND [270]
The control panel will transmit the test report code programmed
into section [717] after the number of days (000 to 255)
programmed into section [261] has elapsed and at the time (00:00
to 23:59) programmed into section [270].
8.8.1 Hourly Test Transmission
SECTION [522]: OPTION [3]
Alternatively, the control panel can transmit the test report code
programmed into section [717] every hour. Turn off option [3] to
disable this feature. Program the minute of each hour (00:00 to
00:59) it sends the test report into section [270].
8.9 Power Fail Report Delay
SECTION [260]
The control panel will delay transmission of the AC Failure report
code programmed into section [712] by the period programmed
into section [260] (000 to 255 minutes).
8.10 Disarm Reporting Options
SECTIONS [506], [510], [514], [518]: OPTION [7]
Since the control panel can enable the Disarm Reporting Options
for each individual partition, select the section that corresponds to
the desired partition and turn option [7] on or off as desired.
Sections [506], [510], [514], [518] represent partitions 1 to 4
respectively.
Report On Disarm After Alarm Only
Option [7] ON
The Digiplex control panel will send Disarming Report Codes (see
section 8.2.3 on page 25) to the monitoring station only when the
system is disarmed following an alarm.
REPORT ON DISARM
Option [7] OFF
The Digiplex control panel will send the Disarming Report Codes
(see section 8.2.3 on page 25) to the monitoring station whenever
a partition is disarmed.
8.11 Zone Restore Report Options
SECTION [522]: OPTION [8]
Report On Zone Closure
Option [8] ON
The control panel will send the Zone Alarm Restore report codes
(see section 8.2.6 on page 25) to the monitoring station as soon as
the zone returns to normal (zone closure) or upon disarming
Report On Bell Cut-off
Option [8] OFF
The control panel will send the Zone Alarm Restore report codes
(see section 8.2.6 on page 25) to the monitoring station when the
Bell Cut-Off Timer has elapsed or when the alarm has been
disarmed (see section 7.2 on page 22).
8.12 Pager Delay
SECTION [259]
When using the Pager Reporting Format (see section 8.5.5 on
page 27), the control panel will wait for the delay period
programmed into section [259] (001 to 060 seconds) before
uploading the report codes to the pager. This is to allow time for the
pager system to provide a dial tone or to bypass the welcome
message before sending data.
8.13 Auto Report Code Programming
SECTIONS [790] TO [795]
When using either the Contact ID or SIA Reporting Formats (see
section 8.5 on page 27), the Digiplex system can automatically
program a set of default report codes. From programming mode
(see section 3.1 on page 9) enter any of the following sections to
set the indicated report codes:
All Codes
Section [790]
Sets all report codes in sections [600] to [718] with the default
values from the Automatic Report Codes List in the Programming
Guide.
Arming & Disarming Codes
Section [791]
Sets all report codes in sections [600] to [654] with the default
values from the Automatic Report Codes List in the Programming
Guide.