12 Installer’s Guide
4.7 BEEP ON EXIT DELAY
Section 003: Option [2]
The keypad can beep once every second during the Exit Delay
Timer. During the final 10 seconds, it will beep more rapidly to
provide a final warning before the area is armed.
Option [2] OFF = Exit Delay beep disabled
Option [2] ON = Exit Delay beep enabled (default)
4.8 CHIME ON ZONE CLOSURE
Section 003: Option [4]
During the Chime Zone Time Period that the user sets, the keypad
can emit an intermittent beep whenever a zone with the Chime
feature enabled closes (see Digiplex User Manual for details on
Chime Zones). If the user does not set the Chime Zone Time Period
and this option is enabled, the Chime Zones will always beep upon
closure.
Option [4] OFF = Chime on Zone Closure disabled (default)
Option [4] ON = Chime on Zone Closure enabled
4.9 BEEP ON TROUBLE
Section 004: Options [1] to [4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a
trouble condition from the Trouble Groups occurs in the system. The
intermittent beep will remain activated until the user enters the
Trouble Display or if the trouble is resolved. For a list of the troubles,
see the Digiplex Control Panel’s Reference and Installation Manual.